Topload Tester (Body bending tester) EH-1000

EH-1000

Easily measurement Ease change bottle type and measurement condition

This equipment is measuring the maximum load and displacement of body bending and displaying the real-time data on computer display and total up the data.

Feature

Target bottle
200 - 2000ml (PET bottle)
Measurement mode selection
  • Initial maximum body bending load and displacement
  • Maximum body bending load and displacement within setting displacement
  • Initial body bending load and displacement within setting displacement
Real-time data display
  • Load bending (Kgf・N)
  • Displacement (mm)
  • Measurement progress chart drawing
  • Total up and decision for standard value
Easy bottle exchange
  • It is possible measurement condition register of 100 model bottles
  • Exchange bottle model and measurement condition by section of registered measurement condition
  • Any measurement of load speed (1 - 300mm/minute, 50mm/minute at shipment)
compatible with automatic measurement
It is possible to measure automatically with robot I/O signal (Option at order)

Spec

Item Content
Target bottle 200 - 2000ml (PET bottle)
Maximum load Load cell 785N (max) (80kgf)
Displacement stroke MAX 220mm
Displacement speed 1 - 300mm/minute (50mm/minute at shipment)
Measurement mode
  1. Initial maximum body bending load measurement
    It is stopped the test when detect initial maximum
    body bending load Data is held displacement when detect maximum load
  2. Maximum body bending load measurement within setting displacement
    It is loading to setting displacement position
    (compress the bottle during body bending)
  3. Initial body bending load measurement within setting displacement
    It is loading to setting displacement position
    (compress the bottle during body bending)
    It prescribes load value initial
    body bending load displacement position within setting displacement. Holding that displacement position.
Size, ・ Weight W900×H1850×D700mm, 70Kg max.
Data output CSV form
Line voltage Selectable 100/120/220/240V 50/60Hz
Safety function
  1. Test is stopped at over load of load cell
    and detection wrong bottle height
    For example, 500ml(205mm height) for 280ml (130mm height) measurement condition
  2. Detection head is stopped detection of up and down limit
  3. Test is stopped at motor error
  4. Equipment is stopped at emergency stop switch [ON]
Interface Correspond to automatic equipment I/O signal
  • Bottle Product
  • Profile